home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

TOR-toroidal (20VA-5kVA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIB for medical devices (0.3:2kVA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

 

UNINTERRUPTIBLE POWER SUPPLIES EB RANGE

from 400VA to 2000VA

EB0400-0600-0800

EB1000-1400-2000

RANGE 400-800VA

MODEL

 

EB 400

EB 600

EB 800

CAPACITY

VA/W

400VA/240W

600VA/360W

800VA/480W

INPUT

Voltage

115VAC or 220/230/240VAC

 

Voltage Range

 85-140VAC  /   162-290VAC

OUTPUT

Voltage

115VAC or 220/230/240VAC

 

Voltage Regulation(Batt. Mode)

±10%

 

Frequency

50Hz or 60Hz

 

Frequency Regulation (Batt. Mode)

+/-1 Hz

 

Output Waveform

Modified Sinewave

BATTERY

Battery Type & Number

6V/4AH x 2pcs

12V/7AH x 1pc

12V/9AH x 1pc

 

Back up Time (at a PC load with 15" monitor)

12 minutes

33 minutes

34 minutes

 

Recharge Time

8 hours to 90% after complete discharge

TRANSFER TIME

Typical

2-6ms

INDICATOR

AC Mode

Green lighting

Battery Mode

Green flashing

AUDIBLE ALARM

Battery Mode

Sounding every 10 seconds

Low Battery

Sounding every second

Overload

Sounding every 0.5 second

Battery Replacement

Sounding every 2 seconds

Fault

Continously sounding

PROTECTION

Full Protection

Discharge, overcharge, and overload protection

PHYSICAL

Dimension, DXWXH (mm)

330X100X140

Net Weight (kgs)

5

6

6,5

ENVIRONMENT

Operating Environment

0- 40°C, 0-90 % relative humidity (non-condensing)

Noise Level

Less than 40dB

INTERFACE

Smart RS-232

Support windows 95/98/NT/2000/XP, Novell, and Linux

DOWNLOAD INSTRUCTION MANUAL (ENGLISH VERSION)

RANGE 1000-2000VA

  MODEL

 

EB 1000

EB 1400

EB 2000

CAPACITY

VA/W

1000VA/600W

1400VA/840W

2000VA/1080W

INPUT

Voltage

115VAC / 220, 230, 240VAC

Voltage Range

 85-140VAC  /   162-290VAC

OUTPUT

Voltage

115VAC / 220, 230, 240VAC

Voltage Regulation (Battery Mode)

±10%

Frequency

50Hz or 60Hz

Frequency Regulation (Battery Mode)

 +/-1 Hz

Output Waveform

Modified Sinewave

BATTERY

Battery Type and Number*

12V/7AH x 2pcs

12V/9AH x 2pc

Back up Time (at 2-PC load with 15" monitor)

23 minutes

25 minutes

26 minutes

Recharge Time

8 Hours to 90% after complete discharge

TRANSFER TIME

Typical

4-6ms

INDICATOR

AC Mode

The 1st green LED lighting

The 2nd to 5th green LEDs gradually lighting indicating load level

Battery Mode

The 1st green LED flashing

The 2nd to 5th green gradually lighting indicating battery capacity

Fault

Red LED lighting

AUDIBLE ALARM

Battery Mode

Sounding every 10 seconds

Low Battery

Sounding every second

Overload

Sounding every 0.5 second

Fault

Continuously sounding

PROTECTION

Full Protection

Discharge, Overcharge, and Overload Protection

PHYSICAL

Dimension, DxWxH (mm)

368.3X140.2X180.4

Net Weight (kgs)

13,8

14,2

16

ENVIRONMENT

Operating Environment

0- 40°C, 0-90 % Relative Humidity (non-condensing)

Noise Level

AC Mode: Less than 40dB

Backup Mode: Less than 45dB

INTERFACE

Smart RS-232

Support Windows 95/98/NT/2000/XP, Novell, and Linux

DOWNLOAD INSTRUCTION MANUAL (ENGLISH VERSION)

HOME PAGE  -  VERSIONE ITALIANA CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice