home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

TOR-toroidal (20VA-5kVA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIB for medical devices (0.3:2kVA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

SINGLE PHASE CONTROL TRANSFORMERS "ITAlia" range

POWER INPUT OUTPUT FREQUENCY STANDARDS
from 50VA to 3000VA 230-400V 12-24V 50/60 Hz EN 61558-2-2
24-48V CEI 96-9
55-110V IEC 989
110-220V BS 171
 Open type
 Protection IP00
 Isolation Class E (Ta max 35°C)
 Separate copper windings cl. F-H
 Resin impregnated and tropicalized
 Protected terminals
 Cable access from front side
 Earth connection on brackets

single phase control transformers

power part no. losses short circuit dimensions mm. DWG weight box
VA W c.c. % A B C D E F kg. code
50 ITA009... 7 11.0 77 60 72 62 48 4 A 1.1 MB01
100 ITA029... 15 8.5 87 65 80 71 53 5 A 1.7 MB01
200 ITA059... 21 5.8 98 80 90 82 70 5 A 3.2 MB02
300 ITA079... 26 4.6 125 80 120 99 64 6 A 4.5 MB03
500 ITA119... 46 4.5 125 100 120 100 84 6 A 5.9 MB03
750 ITA169... 55 3.9 152 100 145 125 93 6 A 8.9 MB04
1000 ITA179... 58 3.9 152 110 140 125 103 6 A 10.9 MB04
1500 ITA199... 77 3.7 152 120 140 125 113 6 A 12.5 MB04
2000 ITA219... 93 3.5 184 120 170 150 122 8 A 18.0 MB05
3000 ITA249... 120 3.5 194 130 180 160 125 8 A 21.2 MB06

to complete de part no. add the following codes to identify the secondary voltage

12-24V 001
24-48V 002
55-110V 003
110-220V 004
 
Power Inrush VA Efficiency Regulation %
VA cos-phi=0.5 cos-phi=0.3 cos-phi=1 cos-phi=0.45 cos-phi=1 cos-phi=0.45
50 85 125 0.80 0.61 6.6 2.6
100 230 310 0.84 0.71 5.2 2.3
200 590 830 0.85 0.73 4.5 2.2
300 745 910 0.88 0.77 5.3 2.8
500 1180 1500 0.91 0.82 4.1 2.2
750 2002 2680 0.93 0.84 3.1 2.0
1000 2690 3390 0.93 0.94 2.5 1.5
1500 4040 4980 0.94 0.87 1.7 1.5
2000 5600 6400 0.95 0.88 1.7 1.5
3000 9400 11600 0.95 0.87 1.7 1.5

DOWNLOAD THE PDF VERSION OF THE CATALOGUE

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice