home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

TOR-toroidal (20VA-5kVA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIB for medical devices (0.3:2kVA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

SINGLE PHASE INDUSTRIAL TRANSFORMERS "MC" RANGE

 
POWER INPUT OUTPUT FREQUENCY STANDARDS
FROM 4000 TO 20000VA 220V 12/24V 50/60 Hz EN 61558-2-1
24/48V CEI 96-4
FROM 110 TO 550V 55/110V CEI 14-4
110/220V BS 171
 Open type
 Protection IP00
 Isolation class E (Amb.temp. max 45°C)
 Separate copper windings cl. F-H
 Resin impregnated and tropicalised
 Connections on terminal blocks up to 10kVA (or up to 63A)
 Coonections on brass bolts from 15kVA (or from 64A)
 optionals: metal enclosure RAL7032, IP23



 

power part no. losses sh. circ. dimensions mm. DWG weight box
VA W volt. % A B C D E F kg. code
4000 MC267... 140 4.8 240 240 320 200 135 12 A 35.0 SA02
5000 MC287... 175 5.2 240 250 320 200 145 12 A 37.0 SA02
7500 MC337... 250 5.0 280 240 400 220 155 12 A 52.0 SA03
10000 MC387... 325 4.6 280 250 400 220 165 12 A 61.0 SA03
15000 MC427... 450 5.0 320 260 450 260 185 12 B 89.0 SA04
20000 MC467... 560 4.8 320 280 450 260 205 12 B 99.0 SA04
ASK PART NOS. AND SPECS. FOR HIGHER RATINGS 

add codes below to complete the part nos. in the above table according to the secondary voltage required

SEC

...

12-24V

030

24-48V

031

55-110V

032

110-220V

033

ASK PART NOS. FOR YOUR CHOICE OF PRIMARY VOLTAGE FROM 110V TO 550V

A

B

power losses inrush VA as a function of cos-phi short circ. regulation
VA W 0.9 0.8 0.7 0.6 0.5 0.4 voltage % %
4000 140 8200 8600 9200 9500 11400 13600 4.8 <5
5000 175 8500 11300 11900 12700 13600 14800 5.2 <5
7500 250 12750 13630 15000 17300 19470 21600 5.0 <5
10000 325 17000 18460 21000 23400 25200 28400 4.6 <5
15000 450 24400 26400 27000 31800 36200 41000 5.0 <5
20000 560 28000 30800 32100 36000 42300 50100 4.8 <5

DOWNLOAD THE PDF VERSION OF THE CATALOGUE

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice