single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

TOR-toroidal (20VA-5kVA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIB for medical devices (0.3:2kVA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

   

SINGLE PHASE LINE CONDITIONERS FOR PROFESSIONAL HI-FI SYSTEMS
"RAF" range

POWER INPUT OUTPUT FREQUENCY SPEED ACCURACY
FROM 1,5KVA TO 2,5KVA 230V ± 20% 230V 50/60 Hz 20 mSEC/V ± 1%

The single phase automatic line conditioners "RAF" have been specifically desinged to supply professional high-end audio systems.
The most developed regulation system wjth a large input range (±20%) is combined with an isolation transformer with earthed copper screen and a combination of RFI-EMI suppression filters which provides a perfect output line with any input conditions. Especially the isolation transformer is involved in this process, being an excellent noise suppressor and protectiong the load from spikes generated by sparks.
On the front panel a digital voltmeter with three leds with input/output voltage reading (analog voltmeter available on request), a practical regulation trimmer, which allows a ±5% regulation on the stabiliserd voltage, and the mains light provide the necessary information and settings, while connections and automatic circuit breaker are placed on the rear side.
You can now appreciate all the performance of your audio system with k-factor line conditioners.

 Power  1,5kVA and 2,5kVA
 Input voltage  230V a.c.
 Input acceptable variation  ± 20% (da 184V a 276V)
 Output voltage  230V a.c.
 Output voltage accuracy  ± 1%
 Frequency  50/60Hz
 Regulation speed  20/1000 sec. / Volt
 Load tolerable variation  da 0 a 100%
 Power factor acceptable variation  0 - 1
 Fulll load efficiency  > 98%
 Harmonic distortion  < 0,5%
 Ambient temperature  0° : 45°C
 Altitude  up to 1000m. above sea level without derating
 Applied standards  IEC 60686
 Protections  2 poles automatic circuit breaker
 Input isolation transformer
 RFI-EMI filter on input-output
 RFI filter protection of control circuit
 Spike protection of control circuit
 Standard accessories  Automatic circuit breaker, digital voltmeter with input/output voltage reading selector, mains light, input/output terminals
 Available options  manual or automatic by-pass
 out of range voltage lights
 remote contact for circuit breaker intervention
 digital A-meter
power part no. dimensions mm. weight
VA L P H kg.
1500 RAF015 340 420 (460) 220 30.0
2500 RAF025 340 420 (460) 220 35.0
schema elettrico condizionatore di rete pr sistemi hi-fi serie RAF ideomat
  • Vin: input voltage

  • mcB: automatic circuit breaker

  • F: In-out filters

  • AT:variable autotransformer

  • TS: buck-boost transformer

  • S: servomotor

  • C: control circuit

  • V: in/out reading voltmeter

  • Vout: regulated voltage

DIFFERENT VOLTAGE AND FREQUENCY AVAILABLE ON REQUEST: 110V,200V,220V,240V,380V,400V,440V AND MORE

REAR SIDE
ON REQUEST WE CAN SUPPLY RAF CONDITIONERS  WITH DIFFERENT ACCESSORIES SUCH AS PLUGS AND MULTIPLE SOCKETS ACCORDING TO MANY DIFFERENT STANDARDS, ADDITIONAL FILTERS AND PROTECTIONS, MEASURING INSTRUMENTS ON THE FRONT PANEL.

MULTI-SOCKET VERSION WITH POWER SUPPLY CABLE.

DONWLOAD INSTRUCTION MANUAL